The purpose of a the dehydration system is to remove water from natural gas and natural gas liquids. When produced from a reservoir, natural gas usually contains a large amount of water and is typically completely saturated or at the water dew point.  This water can cause several problems for downstream processes and  equipment. At low temperatures the water can either freeze in piping or,  as is more commonly the case, form hydrates with CO2  and hydrocarbons (mainly methane hydrates). Depending on composition,  these hydrates can form at relatively high temperatures plugging  equipment and piping. The '''Dehydration Systems''' depress the hydrate formation point of the gas through water removal.
The purpose of a the dehydration system is to remove water from natural gas and natural gas liquids. When produced from a reservoir, natural gas usually contains a large amount of water and is typically completely saturated or at the water dew point.  This water can cause several problems for downstream processes and  equipment. At low temperatures the water can either freeze in piping or,  as is more commonly the case, form hydrates with CO2  and hydrocarbons (mainly methane hydrates). Depending on composition,  these hydrates can form at relatively high temperatures plugging  equipment and piping. The Dehydration Systems depress the hydrate formation point of the gas through water removal.




Without '''Dehydration Systems''', a free water phase (liquid water) could also  drop out of the natural gas as it is either cooled or the pressure is  lowered through equipment and piping. This free water phase will often  contain some portions of acid gas (such as H2S and CO2) and can cause corrosion.
Without Dehydration Systems, a free water phase (liquid water) could also  drop out of the natural gas as it is either cooled or the pressure is  lowered through equipment and piping. This free water phase will often  contain some portions of acid gas (such as H2S and CO2) and can cause corrosion.




For the above two reasons the Gas Processors Association sets out a pipeline quality specification for gas that the water content should not exceed 7 pounds per million cubic feet . The '''Dehydration Systems''' must typically meet this specification at a  minimum, although further removal may be required if additional hydrate  formation temperature depression is required, such as upstream of a cryogenic process or gas plant.
For the above two reasons the Gas Processors Association sets out a pipeline quality specification for gas that the water content should not exceed 7 pounds per million cubic feet . The Dehydration Systems must typically meet this specification at a  minimum, although further removal may be required if additional hydrate  formation temperature depression is required, such as upstream of a cryogenic process or gas plant.