Sump pump systems are also utilized in industrial and commercial applications to control water table-related problems in surface soil. An artesian aquifer or periodic high water table situation can cause the ground to become unstable due to water saturation. As long as the pump functions, the surface soil will remain stable. These sumps are typically ten feet in depth or more; lined with corrugated metal pipe that contains perforations or drain holes throughout. They may include electronic control systems with visual and audible alarms and are usually covered to prevent debris and animals from falling in. | Sump pump systems are also utilized in industrial and commercial applications to control water table-related problems in surface soil. An artesian aquifer or periodic high water table situation can cause the ground to become unstable due to water saturation. As long as the pump functions, the surface soil will remain stable. These sumps are typically ten feet in depth or more; lined with corrugated metal pipe that contains perforations or drain holes throughout. They may include electronic control systems with visual and audible alarms and are usually covered to prevent debris and animals from falling in. | ||
==Types== | ==Types== | ||
There are generally two types of sump pumps -pedestal and submersible. | There are generally two types of sump pumps -pedestal and submersible. | ||
===Pedestal pump=== | ===Pedestal pump=== | ||
The pedestal pump's motor is mounted above the sump, where it is more easily serviced, but is also more conspicuous. The pump impeller is driven by a long, vertical extension shaft and the impeller is in a scroll housing in the base of the pump. | The pedestal pump's motor is mounted above the sump, where it is more easily serviced, but is also more conspicuous. The pump impeller is driven by a long, vertical extension shaft and the impeller is in a scroll housing in the base of the pump. | ||
===Submersible pump=== | ===Submersible pump=== | ||
The submersible pump is entirely mounted inside the sump, and is specially sealed to prevent electrical short circuits. | The submersible pump is entirely mounted inside the sump, and is specially sealed to prevent electrical short circuits. | ||
==Maintenance== | ==Maintenance== | ||
Sump basins and sump pumps must be maintained. Typical recommendations suggest examining equipment every year. Pumps running frequently due to higher water table, water drainage, or weather conditions should be examined more frequently. Sump pumps, being mechanical devices, will fail eventually, which could lead to a flooded basement and costly repairs. Redundancy in the system can help to avoid problems when maintenance and repairs are needed on the primary system. | Sump basins and sump pumps must be maintained. Typical recommendations suggest examining equipment every year. Pumps running frequently due to higher water table, water drainage, or weather conditions should be examined more frequently. Sump pumps, being mechanical devices, will fail eventually, which could lead to a flooded basement and costly repairs. Redundancy in the system can help to avoid problems when maintenance and repairs are needed on the primary system. | ||
Line 28: | Line 27: | ||
Float switches are used to automatically turn the sump pump on when filled to a preset level. Float switches must be clear of any obstructions within the tank. A float guard can be used to prevent the float switch from accidentally resting on on the pump housing, and remaining on. | Float switches are used to automatically turn the sump pump on when filled to a preset level. Float switches must be clear of any obstructions within the tank. A float guard can be used to prevent the float switch from accidentally resting on on the pump housing, and remaining on. | ||
==Sources== | ==Sources== | ||
[http://en.wikipedia.org/wiki/Sump_pump Wikipedia Sump Pump] | [http://en.wikipedia.org/wiki/Sump_pump Wikipedia Sump Pump] |
Latest revision as of 02:25, 23 December 2013
Sump Pumps are Pumps used to remove water that has accumulated in a water collecting sump basin, commonly found in the basement of homes. The water may enter via the perimeter drains of a basement waterproofing system, funneling into the basin or because of rain or natural ground water, if the basement is below the water table level.
Sump pumps are used where basement flooding happens regularly and to remedy dampness where the water table is above the foundation of a home. Sump pumps send water away from a house to any place where it is no longer problematic, such as a municipal storm drain or a dry well.Pumps may discharge to the sanitary sewer in older installations. Once considered acceptable, this practice may now violate the plumbing code or municipal bylaws, because it can overwhelm the municipal sewage treatment system. Municipalities urge homeowners to disconnect and reroute sump pump discharge away from sanitary sewers. Fines may be imposed for noncompliance. Many homeowners have inherited their sump pump configurations and do not realize that the pump discharges to the sewer. If the discharge is fed to a laundry sink in the basement, it's likely going to the sewer.
Usually hardwired into a home's electrical system, sump pumps may have a battery backup. The home's pressurized water supply powers some pumps, eliminating the need for electricity at the expense of using potable water, potentially making them more expensive to operate than electrical pumps and creating an additional water disposal problem. Since a sump basin may overflow if not constantly pumped, a backup system is important for cases when the main power is out for prolonged periods of time, as during a severe storm.
Sump pump systems are also utilized in industrial and commercial applications to control water table-related problems in surface soil. An artesian aquifer or periodic high water table situation can cause the ground to become unstable due to water saturation. As long as the pump functions, the surface soil will remain stable. These sumps are typically ten feet in depth or more; lined with corrugated metal pipe that contains perforations or drain holes throughout. They may include electronic control systems with visual and audible alarms and are usually covered to prevent debris and animals from falling in.
Types
There are generally two types of sump pumps -pedestal and submersible.
Pedestal pump
The pedestal pump's motor is mounted above the sump, where it is more easily serviced, but is also more conspicuous. The pump impeller is driven by a long, vertical extension shaft and the impeller is in a scroll housing in the base of the pump.
Submersible pump
The submersible pump is entirely mounted inside the sump, and is specially sealed to prevent electrical short circuits.
Maintenance
Sump basins and sump pumps must be maintained. Typical recommendations suggest examining equipment every year. Pumps running frequently due to higher water table, water drainage, or weather conditions should be examined more frequently. Sump pumps, being mechanical devices, will fail eventually, which could lead to a flooded basement and costly repairs. Redundancy in the system can help to avoid problems when maintenance and repairs are needed on the primary system.
When examining a sump pump and cleaning it, dirt, gravel, sand, and other debris should be removed to increase efficiency and extend the life of the pump. These obstructions can also decrease the pump's ability to drain the sump, and can allow the sump to overflow. The check valve can also jam from the debris. Examine the discharge line opening, when applicable, to ensure there are no obstructions in the line. Even a partially obstructed discharge line can force a sump pump to work harder and increase its chance of overheating and failure.
Float switches are used to automatically turn the sump pump on when filled to a preset level. Float switches must be clear of any obstructions within the tank. A float guard can be used to prevent the float switch from accidentally resting on on the pump housing, and remaining on.