[[File:Dosing valve.jpg|thumb|right|Dosing Valves]]
* READ THIS FIRST
[[File:Dosing valve1.jpg|thumb|right|Dosing Valves]]
* Only edit this page if you can improve the content.
'''Dosing Valve''' is used to neutralise tailings or to control the PH of the medium.
* Improper use of this page will lead to permanent banning.
Typically, rock lime (alkaline) in a ring main is continuously pumped around the circuit because it tends to settle and separate.  Normally a T piece is inserted into the line (called a take off line) and the flow is controlled with a standard valve i.e knife or butterfly.  When the valve is closed the line is filled up with the stagnant lime and blocks.  The dosing valve eliminates this by being located directly in the ring main. As the valve opens the vertical take off line fills up.  When closed the line gravity flushes thus not leaving a pocket of pipe that can solidify.
* Please do not edit the sponsored link on the top right corner.
 
* Please start editing this page after the /noinclude
 
* -------------------------------------------------></noinclude>
 
This page is still empty. If you know something about this product, please share your knowledge with others.
 
==Applications==
The dosing valve distinguishes itself through precise and reproducible gas inlet and is especially suited for use in:
* Gas and surface analysis
* Mass spectrometry
* Nuclear physics, accelerators
* Cathode sputtering
* Vacuum and laser technology
* Handling of very pure gases

Latest revision as of 03:14, 12 January 2013

Dosing Valves
Dosing Valves

Dosing Valve is used to neutralise tailings or to control the PH of the medium. Typically, rock lime (alkaline) in a ring main is continuously pumped around the circuit because it tends to settle and separate. Normally a T piece is inserted into the line (called a take off line) and the flow is controlled with a standard valve i.e knife or butterfly. When the valve is closed the line is filled up with the stagnant lime and blocks. The dosing valve eliminates this by being located directly in the ring main. As the valve opens the vertical take off line fills up. When closed the line gravity flushes thus not leaving a pocket of pipe that can solidify.



Applications

The dosing valve distinguishes itself through precise and reproducible gas inlet and is especially suited for use in:

  • Gas and surface analysis
  • Mass spectrometry
  • Nuclear physics, accelerators
  • Cathode sputtering
  • Vacuum and laser technology
  • Handling of very pure gases