Difference between revisions of "Viscosity Process Analyzers"

From SolidsWiki
Jump to navigation Jump to search
(Created page with "Category:Analyzing{{Knoppen}} <noinclude><!------------------------------------------------ * READ THIS FIRST * Only edit this page if you can improve the content. * Imprope...")
 
 
Line 1: Line 1:
[[Category:Analyzing]]{{Knoppen}}
[[Category:Analyzing]]{{Knoppen}}
<noinclude><!------------------------------------------------
[[File:Viscosity Process Analyzers.jpg|thumb|right|Viscosity Process Analyzers]]
* READ THIS FIRST
In the '''Viscosity Process Analyzers''' , a capillary type of viscosimeter with external pressure, the pressure drop resulting from a constant flow of a fluid through a capillary of constant dimension is measured as dynamic viscosity.  The measurement is not absolute, i.e. the viscosity process analyzer has to be calibrated with two fluids of known viscosities. For a fluid of constant density the reading of the measured variable may also be interpreted as kinematic viscosity. Varying densities, however, would require measurement of the density for correction.
* Only edit this page if you can improve the content.
 
* Improper use of this page will lead to permanent banning.
The measuring principle is based on the Hagen-Poiseuille Equation.  Continuous volume flow is forced and simultaneously measured by a pneumatically-driven metering cylinder ; piston speed is adjusted so that the differential pressure transmitter is always observed at a pre-selected point of its range .  The entire analyzing procedure is microprocessor-controlled; this includes an automatic and continuous kinetic energy adjustment known as the Hagenbach Correction ; this also includes compensation for varying the piston speeds.  C Temperature control of the oil filled bath is maintained within + 0,05° . Constant sample input temperature should be maintained.  The inlet or outlet valves prior to the cylinder are routinely checked for tight closure . The analyzer cycle time depends on sample parameters .Repeatability and reproducibility are equal or better than the limits indicated in corresponding standards and norms.
* Please do not edit the sponsored link on the top right corner.
* Please start editing this page after the /noinclude
* -------------------------------------------------></noinclude>
This page is still empty. If you know something about this product, please share your knowledge with others.

Latest revision as of 07:45, 29 January 2013

Viscosity Process Analyzers

In the Viscosity Process Analyzers , a capillary type of viscosimeter with external pressure, the pressure drop resulting from a constant flow of a fluid through a capillary of constant dimension is measured as dynamic viscosity. The measurement is not absolute, i.e. the viscosity process analyzer has to be calibrated with two fluids of known viscosities. For a fluid of constant density the reading of the measured variable may also be interpreted as kinematic viscosity. Varying densities, however, would require measurement of the density for correction.

The measuring principle is based on the Hagen-Poiseuille Equation. Continuous volume flow is forced and simultaneously measured by a pneumatically-driven metering cylinder ; piston speed is adjusted so that the differential pressure transmitter is always observed at a pre-selected point of its range . The entire analyzing procedure is microprocessor-controlled; this includes an automatic and continuous kinetic energy adjustment known as the Hagenbach Correction ; this also includes compensation for varying the piston speeds. C Temperature control of the oil filled bath is maintained within + 0,05° . Constant sample input temperature should be maintained. The inlet or outlet valves prior to the cylinder are routinely checked for tight closure . The analyzer cycle time depends on sample parameters .Repeatability and reproducibility are equal or better than the limits indicated in corresponding standards and norms.