Difference between revisions of "Air Blast Coolers"

From SolidsWiki
Jump to navigation Jump to search
 
(8 intermediate revisions by the same user not shown)
Line 1: Line 1:
                            
                            


 
[[Category:Cooling]]{{Knoppen}}
    Air blast cooler sometimes known as Dry Air Coolers, these are ideally suited for a whole range of cooling applications where closed circuit cooling is desirable and cooling to within 3ºC of the prevailing ambient temperature is acceptable all year round.   
<noinclude><!------------------------------------------------
Air Blast Coolers are a practical and cost effective alternative to Water Cooling Towers, which by law have to conform to ACOP L8. The costs of conformance are steep and include:
* READ THIS FIRST
* Only edit this page if you can improve the content.
* Improper use of this page will lead to permanent banning.
* Please do not edit the sponsored link on the top right corner.
* Please start editing this page after the /noinclude
* -------------------------------------------------></noinclude>
[[File:Air-blast coolers.jpg|thumb|right|Air Blast Coolers]]
'''Air Blast Cooler''' sometimes known as [[Dry Coolers]], these are ideally suited for a whole range of cooling applications where closed circuit cooling is desirable and cooling to within 3ºC of the prevailing ambient temperature is acceptable all year round.   
Air Blast Coolers are a practical and cost effective alternative to [[Cooling Towers]], which by law have to conform to ACOP L8. The costs of conformance are steep and include:
   
   


      ♦ Chemical treatment to guard against Legionella
* Chemical treatment to guard against Legionella
      ♦ Water softening to prevent lime scale formation
      ♦ Treatment and safe disposal of effluent resulting from routine cleaning and draining
      ♦ Water losses and make up due to constant evaporation can also be a significant operational cost.
 
 
  [[File:Air-blast coolers.jpg]]
 


* Water softening to prevent lime scale formation


* Treatment and safe disposal of effluent resulting from routine cleaning and draining


* Water losses and make up due to constant evaporation can also be a significant operational cost.






==Features==




'''Features'''
* Each will be individually selected to match the load conditions and various configurations are available to meet
                                 
space and noise limitations.
     
* Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands
of kilowatts.


* Control of the water temperature is regulated, by controlling fan speed, according to the prevailing  
      ♦ Each will be individually selected to match the load conditions and various configurations are available to meet
ambient temperature.
        space and noise limitations.
      ♦ Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands
        of kilowatts.
      ♦ Control of the water temperature is regulated, by controlling fan speed, according to the prevailing  
        ambient temperature.

Latest revision as of 12:38, 4 August 2012


Air Blast Coolers

Air Blast Cooler sometimes known as Dry Coolers, these are ideally suited for a whole range of cooling applications where closed circuit cooling is desirable and cooling to within 3ºC of the prevailing ambient temperature is acceptable all year round. Air Blast Coolers are a practical and cost effective alternative to Cooling Towers, which by law have to conform to ACOP L8. The costs of conformance are steep and include:


  • Chemical treatment to guard against Legionella
  • Water softening to prevent lime scale formation
  • Treatment and safe disposal of effluent resulting from routine cleaning and draining
  • Water losses and make up due to constant evaporation can also be a significant operational cost.


Features

  • Each will be individually selected to match the load conditions and various configurations are available to meet

space and noise limitations.

  • Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands

of kilowatts.

  • Control of the water temperature is regulated, by controlling fan speed, according to the prevailing

ambient temperature.