[[File:Compressed-air-dryer-826445.jpg|thumb|right|200Px|Compressed Air Dryer]]
[[File:Compressed_Air_Dryers.jpg|thumb|right|200Px|Compressed Air Dryers]]
'''Compressed Air Dryers''' are commonly found in a wide  range of industrial and commercial facilities. The [[Air Dryers]] are used to remove water vapor from compressed air.
'''Compressed Air Dryers''' are commonly found in a wide  range of industrial and commercial facilities. The [[Air Dryers]] are used to remove water vapor from compressed air.
The  process of air compression concentrates atmospheric contaminants,  including water vapor. This raises the dew point of the compressed air  relative to free atmospheric air and leads to condensation within pipes  as the compressed air cools downstream of the compressor.
The  process of air compression concentrates atmospheric contaminants,  including water vapor. This raises the dew point of the compressed air  relative to free atmospheric air and leads to condensation within pipes  as the compressed air cools downstream of the compressor.
Excessive  water in compressed air, in either the liquid or vapor  phase, can  cause a variety of operational problems for users of  compressed air.  These include freezing of outdoor air lines, corrosion  in piping and  equipment, malfunctioning of pneumatic process control  instruments,  fouling of processes and products, and more.
Excessive  water in compressed air, in either the liquid or vapor  phase, can  cause a variety of operational problems for users of  compressed air.  These include freezing of outdoor air lines, corrosion  in piping and  equipment, malfunctioning of pneumatic process control  instruments,  fouling of processes and products, and more.
There are various types of compressed air dryers. Their performance characteristics are typically defined by the dew point.
There are various types of compressed air dryers. Their performance characteristics are typically defined by the dew point.
* [[Regenerative Desiccant Dryers]], often called [[Regens]] or [[Twin Tower Dryers]]
* [[Regenerative Desiccant Dryers]], often called [[Regens]] or [[Twin Tower Dryers]]
* [[Refrigerated Dryers]]
* [[Refrigerated Dryers]]
* [[Deliquescent Dryers]]  
* [[Deliquescent Dryers]]  
* [[Membrane Dryers]]
* [[Membrane Dryers]]
Water  vapor is removed from compressed air to prevent condensation  from  occurring and to prevent moisture from interfering in sensitive  industrial processes.
Water  vapor is removed from compressed air to prevent condensation  from  occurring and to prevent moisture from interfering in sensitive  industrial processes.


Line 26: Line 30:




==Refrigerated dryer==
==Refrigerated Dryer==
Refrigeration  dryers employ two heat exchangers,  one for air-to-air and one for  air-to-refrigeration. However, there is  also a single TRISAB heat  exchanger that combines both functions. The compressors used in this  type of dryer are usually of the hermetic type and the most common gas  used is R-134a.  The goal of having two heat exchangers is that the cold  outgoing air  cools down the hot incoming air and reduces the size of  compressor  required. At the same time the increase in the temperature  of outgoing  air prevents re-condensation.
Refrigeration  dryers employ two heat exchangers,  one for air-to-air and one for  air-to-refrigeration. The goal of having two heat exchangers is that the cold  outgoing air  cools down the hot incoming air and reduces the size of  compressor  required. At the same time the increase in the temperature  of outgoing  air prevents re-condensation.


Most  manufacturers produce "cycling dryers". These store a cold mass  that  cools the air when the compressor is OFF. When the refrigeration  compressor runs, the large mass takes much longer to cool, so the  compressor runs longer, and stays OFF longer. These units operate at   lower dew points, typically in the 35–40 °F range. When selected with  the optional "cold coalescing filter", these units can deliver  compressed air with lower dew points.
 
Some manufacturers are  marketing compressors with built-in  refrigeration dryers, but these  have had a mixed acceptance in the  market.
Most  manufacturers produce "cycling dryers". These store a cold mass  that  cools the air when the compressor is OFF. When the refrigeration  compressor runs, the large mass takes much longer to cool, so the  compressor runs longer, and stays OFF longer. These units operate at lower dew points, typically in the 35–40 °F range. When selected with  the optional "cold coalescing filter", these units can deliver  compressed air with lower dew points.
Commonly a coalesing  prefilter is installed immediately upstream of a  refrigerated dryer to  remove lubricating oil and other contaminants  that have the potential  to foul the dryer's heat exchangers.
Commonly a coalesing  prefilter is installed immediately upstream of a  refrigerated dryer to  remove lubricating oil and other contaminants  that have the potential  to foul the dryer's heat exchangers.




==Deliquescent dryer==  
==Deliquescent Dryer==
A deliquescent dryer typically consists of a pressure vessel filled  with a hygroscopic media that absorbs water vapor. The media gradually  dissolves—or deliquesces—to form a solution at the base of the pressure  vessel. The liquid must be regularly drained from the vessel and new  media must be added. The media is usually in tablet or briquette form.
A deliquescent dryer typically consists of a pressure vessel filled  with a hygroscopic media that absorbs water vapor. The media gradually  dissolves—or deliquesces—to form a solution at the base of the pressure  vessel. The liquid must be regularly drained from the vessel and new  media must be added. The media is usually in tablet or briquette form.
Deliquescent  dryers have no moving parts and don't require electrical  power for  operation. Common applications therefore often involve  remote,  hazardous, or mobile worksites. Deliquescent dryers are used for  removing water vapor from compressed air, natural gas, and waste gases  such as landfill gas and digester gas.
Deliquescent  dryers have no moving parts and don't require electrical  power for  operation. Common applications therefore often involve  remote,  hazardous, or mobile worksites. Deliquescent dryers are used for  removing water vapor from compressed air, natural gas, and waste gases  such as landfill gas and digester gas.
Line 40: Line 44:




==Desiccant dryer==  
==Desiccant Dryer==
The  term  [[Desiccant Dryers]] refers to a broad class of dryers. Other  terms commonly used are regenerative dryer and twin tower dryer, and to a  lesser extent [[Absorption Dryers]].
The  term  [[Desiccant Dryers]] refers to a broad class of dryers. Other  terms commonly used are regenerative dryer and twin tower dryer, and to a  lesser extent [[Absorption Dryers]].
The compressed air is  passed through a pressure vessel filled with an absorbent media such as  activated alumina, silica gel, molecular sieve or other desiccant  material. The desiccant can bring the dew point of the water vapor in  the air down to −40 °C (−40 °F) or below. This means that the air will  not condense (deposition)  water until it is cooled to −40 °C (−40 °F).  In practice, two cylinders  with desiccant are used; one is drying the  air, while the other vessel  is being regenerated. The switching of the  vessels and the regeneration  sequence is typically done automatically  via solenoid operated valves.
The compressed air is  passed through a pressure vessel filled with an absorbent media such as  activated alumina, silica gel, molecular sieve or other desiccant  material. The desiccant can bring the dew point of the water vapor in  the air down to −40 °C (−40 °F) or below. This means that the air will  not condense (deposition)  water until it is cooled to −40 °C (−40 °F).  In practice, two cylinders  with desiccant are used; one is drying the  air, while the other vessel  is being regenerated. The switching of the  vessels and the regeneration  sequence is typically done automatically  via solenoid operated valves. The regeneration of the desiccant vessel can be during three different methods:
The regeneration of the desiccant vessel can be during three different methods:
 
 
* Heatless "pressure-swing" drying, which uses part of the dry compressed air coming from the other vessel to dry the desiccant in the vessel being regenerated at lower pressure.
* Heatless "pressure-swing" drying, which uses part of the dry compressed air coming from the other vessel to dry the desiccant in the vessel being regenerated at lower pressure.
* [[Heated Dryers|Heated dryer]], which uses a hot air blower, so there is no loss of compressed air.
* [[Heated Dryers|Heated dryer]], which uses a hot air blower, so there is no loss of compressed air.
Line 49: Line 54:




==Membrane dryer==  
==Membrane Dryer==
Membrane dryer refers to a dehumidification membrane that removes water vapor from compressed air.
Membrane dryer refers to a dehumidification membrane that removes water vapor from compressed air.
Typically,  the compressed air is first filtered with a high-quality [[Coalescing  Filters|Coalescing Filter]]. This filter removes liquid water, oil and  particulate from the  compressed air. The water vapor–laden air then  passes through the center  bore of hollow fibers in the membrane bundle.  At the same time, a small  portion of the dry air product is redirected  along the outside surface  of the fibers to sweep out the water vapor  which has permeated the  membrane. The moisture-laden sweep gas is then  vented to the atmosphere,  and clean, dry air is supplied to the  application. The membrane air  dryers are designed to operate  continuously, 24 hours per day, 7 days  per week. Membrane air dryers  are quiet, reliable and require no  electricity to operate.
Typically,  the compressed air is first filtered with a high-quality [[Coalescing  Filters|Coalescing Filter]]. This filter removes liquid water, oil and  particulate from the  compressed air. The water vapor–laden air then  passes through the center  bore of hollow fibers in the membrane bundle.  At the same time, a small  portion of the dry air product is redirected  along the outside surface  of the fibers to sweep out the water vapor  which has permeated the  membrane. The moisture-laden sweep gas is then  vented to the atmosphere,  and clean, dry air is supplied to the  application. The membrane air  dryers are designed to operate  continuously, 24 hours per day, 7 days  per week. Membrane air dryers  are quiet, reliable and require no  electricity to operate.
Line 59: Line 64:




==Usage==  
==Usages==
* Drying air for use in commercial or industrial processes that demand dry air
* Drying air for use in commercial or industrial processes that demand dry air
:*Telecomm industry (pressurizes its underground cables to repel moisture and avoid shorts
:*Telecomm industry (pressurizes its underground cables to repel moisture and avoid shorts

Latest revision as of 20:08, 3 August 2012


Compressed Air Dryers

Compressed Air Dryers are commonly found in a wide range of industrial and commercial facilities. The Air Dryers are used to remove water vapor from compressed air. The process of air compression concentrates atmospheric contaminants, including water vapor. This raises the dew point of the compressed air relative to free atmospheric air and leads to condensation within pipes as the compressed air cools downstream of the compressor. Excessive water in compressed air, in either the liquid or vapor phase, can cause a variety of operational problems for users of compressed air. These include freezing of outdoor air lines, corrosion in piping and equipment, malfunctioning of pneumatic process control instruments, fouling of processes and products, and more. There are various types of compressed air dryers. Their performance characteristics are typically defined by the dew point.



Water vapor is removed from compressed air to prevent condensation from occurring and to prevent moisture from interfering in sensitive industrial processes.


Characteristics

  • A regenerative desiccant dryer typically delivers a dew point of between −40 °F(−40 °C) and −100 °F (−73 °C)
  • A refrigerated dryer delivers a dew point not lower than approximately 35 °F (2 °C)
  • A deliquescent dryer delivers a dew point suppression that fluctuates with air temperature. Typically this suppression is 20 °F
below the compressed air temperature.


Refrigerated Dryer

Refrigeration dryers employ two heat exchangers, one for air-to-air and one for air-to-refrigeration. The goal of having two heat exchangers is that the cold outgoing air cools down the hot incoming air and reduces the size of compressor required. At the same time the increase in the temperature of outgoing air prevents re-condensation.


Most manufacturers produce "cycling dryers". These store a cold mass that cools the air when the compressor is OFF. When the refrigeration compressor runs, the large mass takes much longer to cool, so the compressor runs longer, and stays OFF longer. These units operate at lower dew points, typically in the 35–40 °F range. When selected with the optional "cold coalescing filter", these units can deliver compressed air with lower dew points. Commonly a coalesing prefilter is installed immediately upstream of a refrigerated dryer to remove lubricating oil and other contaminants that have the potential to foul the dryer's heat exchangers.


Deliquescent Dryer

A deliquescent dryer typically consists of a pressure vessel filled with a hygroscopic media that absorbs water vapor. The media gradually dissolves—or deliquesces—to form a solution at the base of the pressure vessel. The liquid must be regularly drained from the vessel and new media must be added. The media is usually in tablet or briquette form. Deliquescent dryers have no moving parts and don't require electrical power for operation. Common applications therefore often involve remote, hazardous, or mobile worksites. Deliquescent dryers are used for removing water vapor from compressed air, natural gas, and waste gases such as landfill gas and digester gas. The performance of a deliquescent dryer, as measured by outlet dew point, is highly dependent on the temperature of the air or gas being processed, with cooler temperatures resulting in better performance.


Desiccant Dryer

The term Desiccant Dryers refers to a broad class of dryers. Other terms commonly used are regenerative dryer and twin tower dryer, and to a lesser extent Absorption Dryers. The compressed air is passed through a pressure vessel filled with an absorbent media such as activated alumina, silica gel, molecular sieve or other desiccant material. The desiccant can bring the dew point of the water vapor in the air down to −40 °C (−40 °F) or below. This means that the air will not condense (deposition) water until it is cooled to −40 °C (−40 °F). In practice, two cylinders with desiccant are used; one is drying the air, while the other vessel is being regenerated. The switching of the vessels and the regeneration sequence is typically done automatically via solenoid operated valves. The regeneration of the desiccant vessel can be during three different methods:


  • Heatless "pressure-swing" drying, which uses part of the dry compressed air coming from the other vessel to dry the desiccant in the vessel being regenerated at lower pressure.
  • Heated dryer, which uses a hot air blower, so there is no loss of compressed air.
  • Heat of compression, which can only be used with an oil free compressor.


Membrane Dryer

Membrane dryer refers to a dehumidification membrane that removes water vapor from compressed air. Typically, the compressed air is first filtered with a high-quality Coalescing Filter. This filter removes liquid water, oil and particulate from the compressed air. The water vapor–laden air then passes through the center bore of hollow fibers in the membrane bundle. At the same time, a small portion of the dry air product is redirected along the outside surface of the fibers to sweep out the water vapor which has permeated the membrane. The moisture-laden sweep gas is then vented to the atmosphere, and clean, dry air is supplied to the application. The membrane air dryers are designed to operate continuously, 24 hours per day, 7 days per week. Membrane air dryers are quiet, reliable and require no electricity to operate. Some dryers are non-porous, which means they only permeate water vapor. Non-porous membranes' drying power is only a function of flow rate, pressure. The sweep flow is strictly controlled by an orifice and is not a function of temperature. Porous membranes are modified nitrogen membranes and pass air as well, usually changing the composition of the compressed air by reducing the oxygen content. The only maintenance required is changing the prefilter cartridge twice a year. The performance of porous membranes are dependent on temperature as well as operating pressure and flow. Membrane air dryers depress the incoming dew point. Most dryers have a challenge air dew point and pressure specification. So if the inlet dew point is lower than the specified challenge air then the outlet dew point is even lower than specified. For example, a dryer could be rated at a −40 °F dew point with a challenge of +70 °F dew point and 100 psig. If the incoming air has an inlet dew point of only 32 °F, the outlet dew point will be somewhat less. Pressure also plays a role. If the pressure is higher than the rated specification then the outlet dew point will be lowered. This lowering of the outlet dew point is due to the longer residence time that the air has inside the membrane. Using the spec above, an operating pressure of 120 psig will yield a lower outlet dew point than specified. The extent of the improvement is dependent on the nature of the membrane and could vary among manufacturers. Dew point suppression is not a feature of refrigerated dryers, as they chill the incoming air to a fixed temperature, usually 35 °F. So a lower dew point challenge will not yield a dew point lower than 35 °F. Membrane air dryers are used in pneumatic components, spray painting, laser plenum purge, air bearings, air spindles, medical equipment, air guns and pneumatic brakes for vehicles and trains.


Usages

  • Drying air for use in commercial or industrial processes that demand dry air
  • Telecomm industry (pressurizes its underground cables to repel moisture and avoid shorts
  • Paintin
  • Pneumatic tool
  • Pneumatic control systems
  • Feed air for Zeolite type Oxygen and Nitrogen generators
  • Truck and Train Air brake systems.


Video