Line 12: | Line 12: | ||
The | The Gas Dryers use a burner assembly which is comprised of a control valve with 1 or 2 solenoids (also called coils), a gas jet, an igniter and a sensor. When the dryer is started, the igniter heats up, when the sensor detects the heat, it signals the solenoid on the control valve to open and release the gas which is then lit by the glowing hot igniter. The igniter turns off but the gas jet remains open. The burning jet of gas keeps the sensor warm which keeps the gas valve open, until the thermostat signals the control valve to stop the flow of gas. | ||