The flash cooler system is simple and consists only of a vacuum chamber (the vacuum is created by steam jet vacuum units) into which the concentrate is sprayed. Depending upon the vacuum the concentrate will flash and due to the evaporation, cooling will take place simultaneously resulting in a slight increase of the solids content.
* Improper use of this page will lead to permanent banning.
 
* Please do not edit the sponsored link on the top right corner.
 
* Please start editing this page after the /noinclude
Often the required concentrate temperature is lower than the one obtained in the last effect. Flash coolers are recommended instead of naturally passing the concentrate over a cooling surface, such as a plate heat exchanger, due to the high viscosity at this stage.
* -------------------------------------------------></noinclude>
 
This page is still empty. If you know something about this product, please share your knowledge with others.
 
The flash cooler is mainly used for whey, where it is especially advantageous, as the cooling takes place instantaneously, thereby avoiding problems with crystallization of the lactose, which would create blockages between the plates.

Revision as of 10:08, 28 July 2012

Flash cooler.jpg


The flash cooler system is simple and consists only of a vacuum chamber (the vacuum is created by steam jet vacuum units) into which the concentrate is sprayed. Depending upon the vacuum the concentrate will flash and due to the evaporation, cooling will take place simultaneously resulting in a slight increase of the solids content.


Often the required concentrate temperature is lower than the one obtained in the last effect. Flash coolers are recommended instead of naturally passing the concentrate over a cooling surface, such as a plate heat exchanger, due to the high viscosity at this stage.