Difference between revisions of "Overpressure Relief Valves"

Jump to navigation Jump to search
no edit summary
(Created page with "Category:Valves{{Knoppen}} <noinclude><!------------------------------------------------ * READ THIS FIRST * Only edit this page if you can improve the content. * Improper u...")
 
Line 1: Line 1:
[[Category:Valves]]{{Knoppen}}
[[Category:Valves]]{{Knoppen}}
<noinclude><!------------------------------------------------  
[[File:Overpressure Relief Valves.jpg|thumb|right|Overpressure Relief Valves]]
* READ THIS FIRST
'''Overpressure Relief Valve''' is a one-way valve designed to open automatically to prevent accidental overinflation of a BC’s Air Cell. Can usually be manually activated by means of a pull cord and, as such, can also function as a remote exhaust.
* Only edit this page if you can improve the content.
 
* Improper use of this page will lead to permanent banning.
Separator vessels, storage tanks, [[Heat Exchangers]], columns and certain piping segments etc. are designed to handle certain operating pressure. However combination of a variety of causes may lead to over pressure in these equipments which may exceed the maximum allowable working pressure (MAWP) value.Overpressure relief valves  are used to relieve the pressure in these equipments before it can cross the maximum allowable working pressure, thus protecting the equipment from damage. The overpressure relief valve set point should be such that relief valve will open before the maximum allowable accumulated pressure (MAWP) is reached in the vessel. For this purpose usually a hydraulic calculation should be done for overpressure relief valve discharge line to determine the back pressure at [[Relief Valves]], which on addition to the pressure drop across pressure relief valve gives the pressure accumulation the equipment.
* Please do not edit the sponsored link on the top right corner.
The overpressure relief valve size is based on a minimum relieving flowrate which can prevent the build up of pressure in the protected equipment from exceeding the MAWP limit. For several possible causes of over pressure in the vessel, relieving flowrates are calculated and the maximum of these flowrates is selected for overpressure relief valve sizing. The over pressure cause corresponding to this flowrate is then known to be the governing case for pressure relief valve sizing.
* Please start editing this page after the /noinclude
* -------------------------------------------------></noinclude>
This page is still empty. If you know something about this product, please share your knowledge with others.

Navigation menu