Air blast cooler sometimes known as Dry Air Coolers, these are ideally suited for a whole range of cooling applications where closed circuit cooling is desirable and cooling to within 3ºC of the prevailing ambient temperature is acceptable all year round. | |||
Air Blast Coolers are a practical and cost effective alternative to Water Cooling Towers, which by law have to conform to ACOP L8. The costs of conformance are steep and include: | Air Blast Coolers are a practical and cost effective alternative to Water Cooling Towers, which by law have to conform to ACOP L8. The costs of conformance are steep and include: | ||
♦ Chemical treatment to guard against Legionella | |||
♦ Water softening to prevent lime scale formation | |||
♦ Water losses and make up due to constant evaporation can also be a significant operational cost. | |||
♦ Treatment and safe disposal of effluent resulting from routine cleaning and draining | |||
♦ Water losses and make up due to constant evaporation can also be a significant operational cost. | |||
[[File:Air-blast coolers.jpg]] | [[File:Air-blast coolers.jpg]] | ||
'''Features''' | '''Features''' | ||
♦ Each will be individually selected to match the load conditions and various configurations are available to meet | |||
♦ Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands | space and noise limitations. | ||
♦ Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands | |||
of kilowatts. | |||
♦ Control of the water temperature is regulated, by controlling fan speed, according to the prevailing | |||
ambient temperature. |
Revision as of 09:56, 27 July 2012
Air blast cooler sometimes known as Dry Air Coolers, these are ideally suited for a whole range of cooling applications where closed circuit cooling is desirable and cooling to within 3ºC of the prevailing ambient temperature is acceptable all year round. Air Blast Coolers are a practical and cost effective alternative to Water Cooling Towers, which by law have to conform to ACOP L8. The costs of conformance are steep and include:
♦ Chemical treatment to guard against Legionella
♦ Water softening to prevent lime scale formation
♦ Treatment and safe disposal of effluent resulting from routine cleaning and draining
♦ Water losses and make up due to constant evaporation can also be a significant operational cost.
Features
♦ Each will be individually selected to match the load conditions and various configurations are available to meet space and noise limitations.
♦ Single units can be provided in capacities from 5kW to 2000kW and they can be inter-connected to reach many thousands of kilowatts.
♦ Control of the water temperature is regulated, by controlling fan speed, according to the prevailing ambient temperature.